LYC-30 Mobile Centrifugal Oil Purifier Machine for High Viscocity Gear Oil

Product Description

Technical Features

(1) Adopt efficient imported Germany Brand MANN+HUMMEL centrifugal oil separator,

which is suitable to remove oil solid impurities from lubricating oil, high viscosity gear oil and

the like.

(2) ZHONGNENG unique double-infrared fluid level auto-control systems replace manual

control of oil liquid level

(3) ZHONGNENG unique distinctive dual impurities filtration technology, with the support of

Germany Brand MANN+HUMMEL centrifugal oil separator, to reach the oil cleanness as

lower as grade 6 NAS1638.

(4) Both centrifugal separator and dual impurities filtration system can be worked

independently.

(5) Reliable preheating system, connect with temperature controller, realize temperature

adjustable and controllable.

(6) Connect with two oil storage tanks to guarantee the sound filtration and smoothly

operation of machine.

(7) For high viscosity lube oil, it is advisable to used the centrifugal separator and dual

impurities filtration system together.

(8) Fixed human handle, four wheels with braking achieve easy removing and mobile.

(9) Compact structure design, portable and easy maintenance, is prior choice for high

viscosity gear oil solid impurities removing and oiling.


Working Principle

The LYC-30 mobile centrifugal oil purifier machine has provided two solutions for high viscosity

lubrication oil as below:

(1) Pump the oil into the primary filter to remove the big size impurities, then oil flow preheat oil

tank; to heat the oil to 95℃ by preheating system; furthermore the oil flow to centrifugal

separator to do impurities removing; finally the oil flow out through fine filter by oil outlet

pump. This is the whole purification procedure.

(2) If the oil is too dirty with large amount of impurities, it is advisable for you to choose to

purification by our dual filtration system to remove the big size impurities firstly . After it

finished, pump the oil to the centrifugal separator to do impurities removing and repeat the

solution one.


Maintenance

(1) After a certain period of running, the machine should be checked to see whether:

(2) The electrical control system is safe and reliable;

(3) The temperature controller is sensitive, reliable and accurate;

(4) Oil seals of the pump shaft are broken with leakage;

(5) There is any blockage with the running system and any abnormal noise with pumps or

related motors;

(6) There is any air or oil leakage with the oil running system and at sealing joints.

(7) After each 3000 hours’ running, grease shall be replenished to prevent motors from

being burnt.

(8) If the machine will not be used over 1 month, Place the machine in a dry environment

with the panel door and all valves closed, and the machine proper protected by a

covering.


Product Inquiry